| dc.contributor.author |
Borbor Alvia, Romina Valentina |
|
| dc.contributor.author |
Vera Baque, Allisson Nicole |
|
| dc.contributor.author |
Rojas Cruz, Pedro Pablo, Director |
|
| dc.date.accessioned |
2026-03-23T14:53:44Z |
|
| dc.date.available |
2026-03-23T14:53:44Z |
|
| dc.date.issued |
2025 |
|
| dc.identifier.citation |
Borbor Alvia R.V; Vera Baque A.N (2025) Diseño sismo-resistente de un edificio de 4 pisos localizado en la ciudad de Manta [Proyecto Integrador] Escuela Superior Politécnica del Litoral |
es_EC |
| dc.identifier.uri |
http://www.dspace.espol.edu.ec/handle/123456789/67972 |
|
| dc.description |
Este proyecto evaluó el desempeño estructural y económico de dos sistemas sismorresistentes para un edificio de 4 pisos en Manta. Se comparó la mampostería confinada modelada como puntales (según ASCE 41-17) con un sistema de mampostería aislada (donde se considera solo como carga muerta). El análisis mediante software de elementos finitos bajo las normas NEC-SE-DS y ACI 318-19 demostró que solo el segundo modelo cumplió con los límites de deriva. En contraste, la alternativa con aisladores sísmicos resultó ser 7.11% más económica que el sistema modelado con diagonales a compresión. Se concluye que el sistema con mampostería aislada ofrece la mejor relación costo-beneficio para este caso específico, aunque el modelado con diagonales resulta esencial para comprender el comportamiento estructural real. |
es_EC |
| dc.description.abstract |
This project assessed the structural and economic performance of two seismic-resistant systems for a four-story building in Manta. A comparative analysis was conducted between confined masonry modelled using diagonal struts (in accordance with ASCE 41-17) and an isolated masonry system, wherein the masonry is treated solely as dead load. Finite element analysis performed under the NEC-SE-DS and ACI 318-19 standards demonstrated that only the latter model complied with the allowable drift limits. The alternative utilising seismic isolation exhibited a 7.11% reduction in cost compared to the strut-modelled system. It is concluded that the isolated masonry system offers a superior cost-benefit ratio for this specific application, although the strut-based modelling methodology remains essential for comprehending the actual structural behaviour.
Keywords: Masonry, modelling, struts, seismic, isolator |
es_EC |
| dc.publisher |
ESPOL.FICT |
es_EC |
| dc.subject |
Mampostería |
es_EC |
| dc.subject |
Aislador |
es_EC |
| dc.subject |
Modelado |
es_EC |
| dc.subject |
Puntales |
es_EC |
| dc.subject |
Sísmico |
es_EC |
| dc.title |
Diseño sismo-resistente de un edificio de 4 pisos localizado en la ciudad de Manta |
es_EC |
| dc.type |
Thesis |
es_EC |
| dc.identifier.codigoespol |
T-115855 |
|
| dc.identifier.codigoproyectointegrador |
INGE-2894 |
|