DSpace Repository

Diseño conceptual de un sistema de precalentamiento de agua blanda de alimentación para caldera pirotubular

Show simple item record

dc.contributor.author Moyano Zambrano, Steven Gerardo
dc.contributor.author Tenempaguay Palate, Mauricio Darío
dc.contributor.author Bucaram Carbo, Carlos Javier, Director
dc.date.accessioned 2026-03-06T20:39:25Z
dc.date.available 2026-03-06T20:39:25Z
dc.date.issued 2025
dc.identifier.citation Moyano Zambrano S.G; Tenempaguay Palate M.D. (2025) Diseño conceptual de un sistema de precalentamiento de agua blanda de alimentación para caldera pirotubular [Proyecto Integrador] Escuela Superior Politécnica del Litoral es_EC
dc.identifier.uri http://www.dspace.espol.edu.ec/handle/123456789/67897
dc.description CONDICIMIENTO DE PUBLICACION DE PROYECTO. La creciente demanda energética de los sectores industrializados de cada país conlleva a buscar medidas que economicen la generación de energía en plantas químicas a través del aprovechamiento de las fuentes residuales como los gases de combustión. El presente proyecto se basó en una caldera pirotubular de alimentación intermitente del Laboratorio de Operaciones Unitarias de la ESPOL. La necesidad de incrementar la temperatura del agua de ingreso a la caldera derivó en la idea de diseñar conceptualmente un economizador con forma de banco de tuberías que recupere la energía residente en los humos resultantes de la combustión de Diésel 2. El diseño final del economizador resultó en 28 tubos distribuidos en 7 filas y 4 columnas dentro de una coraza con un largo de 50 cm, ancho de 21.1 cm y altura de 40 cm, que permitirá incrementar la temperatura del agua desde 27°C a 50°C, reduciendo hasta 80°C la temperatura del flujo de gases que inicialmente escapan a 305°C. Se validó el diseño usando el software Aspen HYSYS® obteniendo un ahorro máximo de diésel de 0.18 gal/h, reducción del flujo de gases hasta en un 8%, y un periodo de retorno de inversión de 5 años y 7 meses. es_EC
dc.description.abstract PROJECT PUBLICATION CONDITIONS. The growing energy demand of the industrialized sectors in each country leads to the search for measures to make energy generation more efficient in chemical plants by taking advantage of residual sources such as flue gases. This project was based on a fire-tube boiler with intermittent feed from the Unit Operations Laboratory at ESPOL. The need to increase the temperature of the water entering the boiler led to the conceptual design of an economizer, shaped as a bank of pipes, to recover the energy remaining in the fumes resulting from the combustion of Diesel 2. The final design of the economizer consisted of 28 tubes arranged in 7 rows and 4 columns inside a shell measuring 50 cm in length, 21.1 cm in width, and 40 cm in height. This setup allows the incoming water temperature to be increased from 27°C to 50°C, while reducing the gas flow temperature to 80°C from the initial 305°C. The design was validated using Aspen HYSYS® software, achieving a maximum diesel savings of 0.18 gal/h, a reduction in gas flow of up to 8%, and a payback period of 5 years and 7 months. KEYWORDS: Economizer, Aspen HYSYS, heat transfer, fuel, fire-tube boiler. es_EC
dc.publisher ESPOL.FCNM es_EC
dc.subject Economizador es_EC
dc.subject Caldera pirotubular es_EC
dc.subject Aspen HYSY es_EC
dc.subject Transferencia de calor es_EC
dc.subject Caldera pirotubular es_EC
dc.subject Combustible es_EC
dc.title Diseño conceptual de un sistema de precalentamiento de agua blanda de alimentación para caldera pirotubular es_EC
dc.type Thesis es_EC
dc.identifier.codigoespol T-115786
dc.identifier.codigoproyectointegrador INGE-2883


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account