Please use this identifier to cite or link to this item:
http://www.dspace.espol.edu.ec/handle/123456789/25359
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pacheco Gavilanes, Luis Rafael | - |
dc.contributor.author | Rodriguez Asqui, Cindy Carolina | - |
dc.contributor.author | Soledispa Santana, José Mauricio | - |
dc.contributor.author | Mera Gencón, Cristóbal | - |
dc.date.accessioned | 2014-05-26 | - |
dc.date.available | 2014-05-26 | - |
dc.date.issued | 2014-05-26 | - |
dc.identifier.uri | http://www.dspace.espol.edu.ec/handle/123456789/25359 | - |
dc.description | En el presente trabajo se realiza un análisis energético en los abonados comerciales del Parque Cal ifornia y propone diferentes alternativas para reducir el consumo de energía eléctrica, la mayoría de los locales comerciales poseen equipos eléctricos antiguos e ineficientes entre ellos los equipos de climatización y sistemas de iluminación, que sumado a la falta de mantenimiento producen un consumo excesivo de energía eléctrica. Se empieza analizando el consumo histórico de Guayaquil, la composición de la generación eléctrica del Ecuador y las emisiones de toneladas de CO2 producto del consumo de energía eléctrica del sector comercial de Guayaquil, para constatar la necesidad de administrar la energía eléctrica. Luego se presenta la información del consumo eléctrico de los diferentes comercios del parque comercial Parque Cal ifornia, dando mayor enfoque a aquellos equipos que representan mayor consumo, los mismos que varían dependiendo de la actividad, producto o servicio de cada comercio, para proponer alternativas que requieren inversión y aquellas que no. Finalmente se realiza un estudio de rentabilidad para determinar si se justifica invertir en equipos eficientes y se presentan los beneficios energéticos y económicos que se obtendrían. | es |
dc.description.abstract | This paper develops an energy analysis to the commercial area of Parque California and proposes many alternatives in order to reduce the electrical consumption; most shops have old and ineficient electric equipment, such as HVAC systems and lighting systems, which with a lack of maintenance increases energy consumption. It begins by analyzing the historical consumption of Guayaquil, the structure of the electrical generation of Ecuador and the emissions of tons of CO2 produced by consumed energy in Guayaquil, to verify the need to manage the demand of electrical energy. Then it presents the information of the electricity consumption of diferent shops located in Parque Cal ifornia, focusing on those loads which represent a higher consumption and vary depending on the activity, product or service of each shop to propose alternatives that require investment and those which do not require. Finally a profitability study is done to determine whether is justified to invest in eficient equipment, the energetic and economics benefits that would be obtain are shown. | es |
dc.language.iso | spa | es |
dc.rights | openAccess | - |
dc.subject | CONSUMO ELÉCTRICO | es |
dc.subject | LOCALES COMERCIALES | es |
dc.subject | EQUIPOS EFICIENTES | es |
dc.subject | TONELADAS DE CO2 | es |
dc.title | Administración de la carga y conservación de energía de los consumidores del sector comercial | es |
dc.type | Article | es |
Appears in Collections: | Artículos de Tesis de Grado - FIEC |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Copia de Resumen de tesis LPacheco, Cindy Rodriguez y JSoledispa, director de tesis Ph.D. Cristóbal Mera G. 18 oct 2013.pdf | 1.22 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.