Por favor, use este identificador para citar o enlazar este ítem: http://www.dspace.espol.edu.ec/handle/123456789/67348
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorAguilar León, Brian Steven-
dc.contributor.authorZambrano Ramos, Carlos Eduardo-
dc.contributor.authorCevallos Valdiviezo, Daniel Andrés, Director-
dc.date.accessioned2026-01-20T14:28:09Z-
dc.date.available2026-01-20T14:28:09Z-
dc.date.issued2025-
dc.identifier.citationAguilar León B.S; Zambrano Ramos C.E. (2025). Implementación de un sistema fotovoltaico inteligente con telemetría para autosuficiencia energética del CIDIS-ESPOL [Proyecto Integrador] Escuela Superior Politécnica del Litorales_EC
dc.identifier.urihttp://www.dspace.espol.edu.ec/handle/123456789/67348-
dc.descriptionCONDICIONAMIENTO DE PUBLICACION DE PROYECTO. Se presenta el diseño e implementación de un sistema fotovoltaico con almacenamiento y telemetría para el CIDIS-ESPOL, motivado por la crisis energética de 2024, con el fin de reducir la dependencia de la red, asegurar la continuidad de cargas críticas y optimizar la gestión energética mediante monitoreo inteligente con Cerbo GX MK2 y plataformas VRM/VictronConnect. El desarrollo contempló el dimensionamiento y la reconfiguración del generador a un arreglo 3S3P de nueve paneles, la integración de un controlador Victron MPPT 150/45, inversor Victron, banco de tres baterías de gel de 12 V en paralelo (≈600 Ah), protecciones y tablero; además, se implementó adquisición de datos y telemetría para registrar variables DC/AC y habilitar supervisión local y remota. En las pruebas (15–21 de agosto) la corriente de carga alcanzó 45 A, la autonomía del banco fue de ~3,5 h y la eficiencia global llegó al 88%; el sistema emitió alertas y mantuvo historial, aportando trazabilidad operativa. El ahorro estimado fue ≈ 30 USD/mes; la inversión total ascendió a 9 050,50 USD, con VAN de −5 157 USD y TIR de 0,4%, por lo que la rentabilidad estrictamente financiera resulta limitada. La principal conclusión es que el sistema sí cumple su objetivo de continuidad y resiliencia energética, a pesar de que la configuración de 12 V restringe el desempeño económico, el valor agregado que justifica y habilita futuras ampliaciones de dicha restricción está en la seguridad operativa, sostenibilidad y uso académico.es_EC
dc.description.abstractCONDITION FOR PUBLICATION OF PROJECT. work reports the design and implementation of a photovoltaic system with energy storage and telemetry at CIDIS-ESPOL, prompted by Ecuador’s 2024 power crisis, aiming to reduce grid dependence, guarantee critical-load continuity, and optimize energy management through smart monitoring (Cerbo GX MK2, VRM/VictronConnect). The project was executed by resizing and reconfiguring the generator to a 3S3P array (nine modules) and integrating a Victron MPPT 150/45 charge controller, a Victron inverter, a 12 V gel battery bank (three units in parallel, ≈600 Ah), protections, and a wiring board; data acquisition and telemetry were implemented to log DC/AC variables and enable local and remote supervision. During tests (August 15–21), charging current reached 45 A, battery autonomy was ~3.5 h, and overall efficiency achieved 88%; the platform issued automatic alerts and kept full historical records, improving operational traceability. The estimated saving was about USD 30/month; total investment was USD 9,050.50 with NPV −USD 5,157 and IRR 0.4%, indicating limited financial profitability alone. It is concluded that the system meets its continuity and resilience goals; despite 12 V configuration constraints on financial performance, added value in operational security, sustainability, and academic use justifies the solution and enables future expansions. Keywords: Photovoltaic system; Telemetry; Cerbo GX MK2; Energy self-sufficiency; Remote monitoring.es_EC
dc.publisherESPOL.FIECes_EC
dc.subjectSistema fotovoltaicoes_EC
dc.subjectTelemetríaes_EC
dc.subjectCerbo GX MK2es_EC
dc.subjectAutosuficiencia energéticaes_EC
dc.subjectMonitoreo remotoes_EC
dc.titleImplementación de un sistema fotovoltaico inteligente con telemetría para autosuficiencia energética del CIDIS-ESPOLes_EC
dc.typeThesises_EC
dc.identifier.codigoespolT-115486-
dc.identifier.codigoproyectointegradorINGE-2919-
Aparece en las colecciones: Tesis de Electrónica y Automatización

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-115486 INGE-2919 AGUILAR- ZAMBRANO.pdf1.9 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.