Por favor, use este identificador para citar o enlazar este ítem:
http://www.dspace.espol.edu.ec/handle/123456789/68374Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.author | García Rivera, Malena Aimee | - |
| dc.contributor.author | Diaz Diaz, Hamilton Miguel | - |
| dc.contributor.author | Orozco Chávez, Víctor Manuel, Director | - |
| dc.date.accessioned | 2026-05-18T20:18:41Z | - |
| dc.date.available | 2026-05-18T20:18:41Z | - |
| dc.date.issued | 2025 | - |
| dc.identifier.citation | García Rivera M.A, Diaz Diaz H.M. (2025) Evaluación técnica y económica de variantes de iluminación natural para un edificio de oficinas de hasta tres plantas utilizando herramientas BIM [Tesis Maestría] Escuela Superior Politécnica del Litoral. Guayaquil, 103 páginas | es_EC |
| dc.identifier.uri | http://www.dspace.espol.edu.ec/handle/123456789/68374 | - |
| dc.description | Este trabajo se centra en evaluar técnica y económicamente variantes de iluminación natural aplicadas a un edificio de oficinas de hasta tres plantas, mediante el uso de herramientas BIM. El proyecto busca optimizar el aprovechamiento de la iluminación natural para reducir el uso de la iluminación artificial, así como también el costo energético asociado, sin afectar el confort térmico de los ocupantes del edificio. La iluminación natural es un factor clave del diseño arquitectónico por su impacto en la calidad de los ambientes, ya que genera diseños más iluminados, funcionales y agradables para los usuarios. En este estudio se modeló el edificio en el software Revit y se realizaron las simulaciones energéticas y lumínicas en el plugin Sefaira, considerando distintas relaciones window/wall ratio (WWR) y tipos de cristalerías, evaluando indicadores como sDA, ASE y EUI con ayuda de las normativas ASHRAE y NEC-HS-EE. Se realizaron algunas simulaciones, concluyendo que mediante la reducción de áreas acristaladas en un 53% con respecto a la línea base, incorporando ventanas tipo recámara con vidrio claro más cámara de aire, modelando voladizos en la parte superior de las ventanas, la simulación #23 logró mejorar la iluminación natural con respecto a la línea base, con un consumo energético cercano al de la línea base. Además, el uso e incorporación de herramientas BIM permite realizar diseños más eficientes y sostenibles en edificaciones de oficinas | es_EC |
| dc.description.abstract | This work focuses on the technical and economic evaluation of natural lighting options for an office building of up to three stories, using BIM tools. The project aims to optimize the use of natural light to reduce the need for artificial lighting, as well as the associated energy costs, without compromising the thermal comfort of the building's occupants. Natural lighting is a key factor in architectural design due to its impact on the quality of environments, as it creates brighter, more functional, and more pleasant spaces for users. In this study, the building was modeled in Revit software, and energy and lighting simulations were performed using the Sefaira plugin, considering different window-towall ratios (WWR) and glazing types. Indicators such as sDA, ASE, and EUI were evaluated using ASHRAE and NEC-HS-EE standards. Several simulations were performed, concluding that by reducing glazed areas by 53% compared to the baseline, incorporating bedroom-type windows with clear glass and an air gap, and modeling overhangs at the top of the windows, simulation #23 improved natural lighting compared to the baseline, with energy consumption close to that of the baseline. Furthermore, the use and integration of BIM tools allows for more efficient and sustainable designs in office buildings. Keywords: Natural lighting, energy efficiency, building envelope, Sefaira | es_EC |
| dc.publisher | ESPOL.FICT | es_EC |
| dc.subject | Iluminación natural | es_EC |
| dc.subject | Eficiencia energética | es_EC |
| dc.subject | Envolvente | es_EC |
| dc.subject | Sefaira | es_EC |
| dc.title | Evaluación técnica y económica de variantes de iluminación natural para un edificio de oficinas de hasta tres plantas utilizando herramientas BIM | es_EC |
| dc.type | Thesis | es_EC |
| dc.identifier.codigoespol | T-116052 | - |
| dc.identifier.codigo | POSTG203 | - |
| Aparece en las colecciones: | Tesis de Maestría en Ingeniería Civil con mención en Construcción y Saneamiento | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| T-116052 POSTG203 GARCIA-DIAZ.pdf | 9.18 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.