DSpace Repository

Verificación del método analítico por HPLC para la valoración de Nitazoxanida en materia prima farmacéutica

Show simple item record

dc.contributor.author Berrús Jiménez, Helen Ellinor
dc.contributor.author Araque Molina, César Augusto, Director
dc.date.accessioned 2026-07-01T20:32:41Z
dc.date.available 2026-07-01T20:32:41Z
dc.date.issued 2026
dc.identifier.citation Berrús Jiménez H.E. (2026) Verificación del método analítico por HPLC para la valoración de Nitazoxanida en materia prima farmacéutica [Tesis Maestría] Escuela Superior Politécnica del Litoral. Guayaquil, 109 páginas es_EC
dc.identifier.uri http://www.dspace.espol.edu.ec/handle/123456789/69246
dc.description En el presente trabajo se realizó la verificación del método analítico por cromatografía líquida de alta eficiencia (HPLC) para la valoración cuantitativa de nitaxozanida en materia prima farmacéutica, conforme a los lineamientos de la ICH Q2(R1), la USP <1225> y la guía EURACHEM. El desempeño del método fue evaluado mediante los parámetros de repetibilidad, precisión intermedia, exactitud, especificidad y linealidad. La repetibilidad mostró un coeficiente de variación (%RSD) de 0,589 %, mientras que la precisión intermedia presentó un %RSD de 1,13 %, cumpliendo con los criterios de aceptación establecidos. La exactitud, evaluada por estudios de recuperación a niveles del 80, 100 y 120 %, arrojó valores promedio entre 98,94 % y 99,60 %, sin diferencias estadísticamente significativas entre niveles (p > 0,05). La especificidad fue confirmada mediante estudios de estrés térmico y análisis de pureza de pico con detector PDA, demostrando ausencia de interferencias. La linealidad fue adecuada en el rango de 0,062 a 0,145 mg/mL, con un coeficiente de determinación R² = 0,9990. Adicionalmente, la estimación de la incertidumbre de medición mostró un resultado de 99,37 % ± 0,95 % (k = 2), confirmando la confiabilidad metrológica del método. En conclusión, el método verificado es preciso, exacto, específico y apto para su aplicación en control de calidad farmacéutico. es_EC
dc.description.abstract In this study, the analytical method by high-performance liquid chromatography (HPLC) for the quantitative assay of nitazoxanide in pharmaceutical raw material was verified in accordance with ICH Q2(R1), USP <1225>, and EURACHEM guidelines. The method performance was evaluated through the parameters of repeatability, intermediate precision, accuracy, specificity, and linearity. Repeatability showed a relative standard deviation (%RSD) of 0.589%, while intermediate precision presented a %RSD of 1.13%, meeting the established acceptance criteria. Accuracy was assessed by recovery studies at 80%, 100%, and 120% concentration levels, yielding average recoveries between 98.94% and 99.60%, with no statistically significant differences among levels (p > 0.05). Specificity was demonstrated using thermal stress studies and peak purity analysis with a photodiode array (PDA) detector, confirming the absence of interference from degradation products or matrix components. Linearity was verified over a concentration range of 0.062 to 0.145 mg/mL, with a coefficient of determination (R²) of 0.9990. Additionally, measurement uncertainty estimation resulted in a final value of 99.37% ± 0.95% (k = 2), confirming the method’s metrological reliability. In conclusion, the verified HPLC method is precise, accurate, specific, and suitable for routine quality control of nitazoxanide pharmaceutical raw material. es_EC
dc.publisher ESPOL.FCNM es_EC
dc.subject Verificación es_EC
dc.subject Método analítico es_EC
dc.subject HPLC es_EC
dc.subject Valoración de Nitazoxanida es_EC
dc.subject Materia prima es_EC
dc.subject Farmacéutica es_EC
dc.title Verificación del método analítico por HPLC para la valoración de Nitazoxanida en materia prima farmacéutica es_EC
dc.type Thesis es_EC
dc.identifier.codigoespol T-116333
dc.identifier.codigo POSTG062


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account